Construction Unit Converters UK 2026 | MPa, kN, mm, Pressure & Load Conversion Tools

Construction Unit Converters UK

MPa · kN · kN/m² · mm · Tonnes · PSI · Bar · Feet · Inches – Instant Engineering Converters

Pressure / Stress – All-in-One Converter

Type any value – all others update instantly.

MPa ↔ PSI

MPa
⇅
PSI

1 MPa = 145.038 PSI  |  1 PSI = 0.006895 MPa


Common values: Concrete C30/37 = 30 MPa cylinder = 4,351 PSI

MPa ↔ kN/m² (kPa)

MPa
⇅
kN/m²

1 MPa = 1,000 kN/m² = 1,000 kPa  |  1 kN/m² = 0.001 MPa


EC2: Steel yield fy = 275 N/mm² = 275,000 kN/m²

N/mm² ↔ kgf/cm²

N/mm²
⇅
kgf/cm²

1 N/mm² = 10.197 kgf/cm²  |  Used in older BS / IS codes

Bar ↔ PSI

Bar
⇅
PSI

1 bar = 14.504 PSI  |  1 PSI = 0.06895 bar


Note: 1 bar ≈ 100 kPa ≈ 0.987 atm; water pressure at 10m depth ≈ 1 bar

Stress & Pressure Quick Reference – Construction Engineering

ValueMPa (N/mm²)kN/m²PSIBarkgf/cm²
Concrete C20/25 (fck cube)2525,0003,626250255
Concrete C30/37 (fck cube)3737,0005,366370377
Concrete C40/50 (fck cube)5050,0007,252500510
Steel S275 yield (fy)275275,00039,8852,7502,804
Steel S355 yield (fy)355355,00051,4883,5503,620
Steel S275 ultimate (fu)430430,00062,3664,3004,385
Rebar B500B yield (fyk)500500,00072,5195,0005,099
Atmospheric pressure0.101325101.32514.6961.0131.033
Water at 10m depth0.0989814.220.981.0
Tyre pressure (typical car)0.207–0.241207–24130–352.07–2.412.11–2.46
Modulus of elasticity – Steel (E)210,000210,000,00030,458,0002,100,0002,141,000
Modulus of elasticity – Concrete C30~33,00033,000,0004,786,000330,000336,600

Force & Load – All-in-One Converter

Type any value – all others update instantly.

kN ↔ Tonnes-force

kN
⇅
tonnes-force

1 tf = 9.807 kN  |  1 kN = 0.1020 tf ≈ 102 kgf

kN/m ↔ kgf/m (UDL)

kN/m
⇅
kgf/m

Uniformly distributed load  |  1 kN/m = 101.97 kgf/m

kN/m² ↔ kgf/m² (pressure / load)

kN/m²
⇅
kgf/m²

1 kN/m² = 101.97 kgf/m²  |  1 kgf/m² = 0.00981 kN/m²

kN ↔ lbf / kip

kN
⇅
lbf

1 kN = 224.809 lbf = 0.2248 kip (1 kip = 1,000 lbf = 4.448 kN)

Force & Distributed Load Quick Reference

Value / ContextkNNkgf (approx.)lbfNotes
Weight of 1 tonne mass9.8079,8071,0002,205g = 9.807 m/s²
Domestic floor imposed load (1.5 kN/m²) on 3m×5m22.5 kN22,5002,2945,059EC1 Cat A residential
Point load from 100kg person0.981981100220—
Self-weight of 203×133×25 UB per metre0.24624625.15525.1 kg/m × 9.807
Self-weight RC slab 150mm on 1m² plan3.753,75038384325 kN/m³ × 0.15m
Wind pressure on wall (0.8 kN/m²) on 10m²8.08,0008161,798—
Typical 2-storey house column reaction100–400—10,000–40,00022,480–89,924Depends on loading bay

Length & Distance – All-in-One Converter

mm ↔ inches

mm
⇅
inches

1 inch = 25.4 mm exactly  |  1 mm = 0.03937 in

m ↔ feet & inches

metres
⇅
ft in

1 ft = 0.3048 m  |  1 m = 3 ft 3.37 in

mm ↔ cm ↔ m

mm
cm
m

Most commonly used length units in UK structural engineering

Beam Section Properties – cm⁴ ↔ mm⁴ ↔ in⁴

cm⁴
mm⁴
in⁴

Second moment of area  |  1 cm⁴ = 10,000 mm⁴ = 0.02403 in⁴

Length Conversion Quick Reference

mmcmminchesfeetCommon context
10.10.0010.039370.003281Rebar cover tolerance, tile grout
101.00.0100.39370.03281Mortar joint, cover tolerance Δcdev
252.50.0250.9840.0820Concrete cover – XC1 (1 inch)
25.42.540.02541.0000.0833Exactly 1 inch
404.00.0401.5750.1312Concrete cover – XC4 external
10010.00.1003.9370.3281Min slab thickness, insulation depth
15015.00.1505.9060.4921Standard RC slab thickness
30530.50.30512.001.000Exactly 1 foot (304.8mm rounded)
91491.40.91436.003.0001 yard
1,000100.01.00039.373.2811 metre
3,048304.83.048120.010.0010 feet

Area – All-in-One Converter

Area Quick Reference – Construction

m²cm²mm²ft²in²Context
0.0001131.131113.10.001220.1754T12 rebar cross-section area (1 bar)
0.0002012.011201.10.002160.3117T16 rebar cross-section area (1 bar)
0.0003933.927392.70.004230.6090A393 mesh (393 mm²/m per metre width)
1.010,0001,000,00010.7641,5501 square metre
9.2992,9039,290,30410014,400100 sq ft
20200,00020,000,000215.331,000Typical medium extension footprint

Volume & Flow – All-in-One Converter

Volume Quick Reference – Concrete & Construction

m³litresft³yd³Context
0.090903.180.118One 130L drum mixer load (usable output)
0.550017.660.654Approx. volume of one bulk aggregate bag
1.01,00035.311.3081 m³ – standard concrete ordering unit
4.04,000141.35.232Typical ready-mix minimum load
6.06,000211.97.848Full ready-mix truck load (UK, 6–8 m³)
7.07,000247.29.153Max ready-mix load (most UK trucks)

Mass & Weight – All-in-One Converter

Mass Quick Reference – Materials & Deliveries

kgtonneslbsContext
250.02555.1Standard bag (cement, sand, aggregate, mortar)
8500.851,874Standard UK bulk bag (jumbo / tonne bag – nominal)
1,0001.02,2051 tonne – standard UK aggregate ordering unit
2,5002.55,512Self-weight of 1 m³ reinforced concrete
7,8507.8517,306Self-weight of 1 m³ structural steel
20,00020.044,092Max payload – standard 4-axle tipper truck (UK)
30,00030.066,139Max payload – artic tipper (UK road weight)

Density & Unit Weight – All-in-One Converter

Density & Unit Weight – Common Construction Materials

Materialkg/m³kN/m³g/cm³lb/ft³
Reinforced concrete2,50024.52.50156
Plain concrete (unreinforced)2,30022.62.30144
Aerated concrete block (AAC)6005.90.6037
Structural steel7,85077.07.85490
Aluminium (structural alloy)2,70026.52.70169
Softwood timber (dry, C24)4204.10.4226
Hardwood timber (dry, oak)7507.40.7547
Clay brick (facing)1,90018.61.90119
Clay brick (engineering)2,10020.62.10131
Sand (dry, loose)1,50014.71.5094
Gravel / shingle (loose)1,60015.71.60100
MOT Type 1 (compacted)2,10020.62.10131
Water (at 4°C)1,0009.811.0062.4
Seawater1,02510.051.02564

Bending Moment & Torque – All-in-One Converter

Bending Moment Quick Reference

ScenariokN·mN·mmkgf·mft·lbf
Simply supported beam – UDL: M = wL²/8e.g. w=10kN/m, L=5m → M = 31.25 kN·m
w=10 kN/m, L=5m (wL²/8)31.2531,250,0003,18623,043
w=20 kN/m, L=6m (wL²/8)90.090,000,0009,17466,371
Cantilever – UDL: M = wL²/2e.g. w=5kN/m, L=2m → M = 10 kN·m
P=100kN at mid-span of 5m SS beam (PL/4)125125,000,00012,74292,173
Elastic section modulus – 203×133×25 UB (Zx)Zx = 231 cm³ = 231,000 mm³; capacity at S275: M = 275 × 231,000 / 10⁶ = 63.5 kN·m

Temperature – All-in-One Converter

U-value ↔ R-value

W/m²K
⇅
m²K/W

R = 1/U  |  U = 1/R  |  Higher R = better insulation; Lower U = better insulation

Thermal Conductivity λ → Resistance R

λ W/mK
mm
m²K/W

R = thickness(m) / λ  |  e.g. 100mm PIR (λ=0.023): R = 0.1/0.023 = 4.35 m²K/W

W/mK ↔ BTU·in/(h·ft²·°F)

W/mK
⇅
BTU·in/(h·ft²·°F)

Imperial thermal conductivity unit  |  1 W/mK = 6.933 BTU·in/(h·ft²·°F)

Thermal Reference – U-values, R-values and λ

Material / Elementλ (W/mK)ThicknessR (m²K/W)U (W/m²K)
PIR board insulation0.023100mm4.350.23
PIR board insulation0.023150mm6.520.15
EPS expanded polystyrene0.036100mm2.780.36
Mineral wool quilt0.038200mm5.260.19
Mineral wool quilt0.038270mm (loft)7.110.14
Cavity wall (full-fill mineral wool)0.036100mm cavity2.78—
Dense concrete2.00200mm0.10—
Brick (facing)0.77102.5mm0.133—
Plasterboard0.2112.5mm0.060—
Internal surface resistance Rsi (wall)——0.13—
External surface resistance Rse——0.04—

Slope & Angle – All-in-One Converter

Slope & Roof Pitch Quick Reference

DescriptionDegrees% Gradient1 in NRadians
Minimum drainage fall (flat roof)1.1°2%1:500.020
Min. fall BS 5534 pitched roof to gutter0.6°1%1:1000.010
Minimum pitched roof – concrete tiles (BS 5534)15°26.8%1:3.730.262
Typical domestic pitched roof (30°)30°57.7%1:1.730.524
Minimum slate – natural (BS 5534)20°36.4%1:2.750.349
Maximum stair pitch (Building Regs Part K)42°90.0%1:1.110.733
Ramp gradient – wheelchair accessible (Part M)3.4°6%1:16.70.059
Ramp gradient – general (Part K)5.7°10%1:100.100
Road camber (typical UK)1.1–2.3°2–4%1:25–1:50—
45° (equal rise and run)45°100%1:10.785
Angle of repose – dry sand~34°~67%~1:1.480.593
Angle of repose – clay~15–35°26–70%1:1.4–1:3.7—

Construction Unit Conversion Guide – UK Engineering 2026

UK construction and structural engineering uses SI (Système International) units as the primary system, following the adoption of Eurocodes and BS EN standards. However, engineers regularly encounter non-SI units in older British Standards, American references, material datasheets, and contractor-supplied data — making unit conversion an everyday requirement in UK construction practice in 2026.

The most frequently converted units in UK structural and civil engineering are: stress and pressure (MPa / N/mm² to PSI and kgf/cm²); force and load (kN to tonnes-force and lbf); length (mm to inches and feet); and bending moment (kN·m to kgf·m and ft·lbf). The converters above cover all of these and more, with quick-reference tables of common engineering values in each unit system.

MPa and N/mm² are Identical

1 MPa = 1 N/mm² exactly. This is because 1 Pa = 1 N/m², and 1 m² = 10⁶ mm², so 1 MPa = 10⁶ N/m² = 1 N/mm². Concrete strength (fck), steel yield strength (fy), and elastic modulus (E) are all expressed in N/mm² (= MPa) in UK Eurocodes. The unit N/mm² is used in most UK structural calculations; MPa is used more often in concrete technology and testing contexts.

kN/m² = kPa

1 kN/m² = 1 kPa (kilopascal) exactly, because 1 kN = 1,000 N and 1 m² = 1 m². Imposed floor loads, wind pressures, and soil bearing pressures are all expressed in kN/m² in Eurocode structural design. The soil bearing pressure for a strip foundation, the wind pressure on a cladding panel, and the live load on a floor slab are all in kN/m².

1 Tonne ≠ 1 Tonne-force

A tonne (t) is a unit of mass (1,000 kg). A tonne-force (tf) is a unit of force equal to the weight of 1 tonne mass under standard gravity (g = 9.80665 m/s²), i.e. 1 tf = 9.807 kN. In everyday construction contexts, "tonnes" is often loosely used to mean "tonnes-force" — important to distinguish when converting to kN for structural calculations.

PSI – Still Used in Some Contexts

PSI (pounds per square inch) is an imperial pressure unit not used in UK Eurocode design but still encountered in: US structural references; some material datasheets (adhesives, sealants, gas pressures); hydraulic system specifications; and tyre pressures. 1 MPa = 145.038 PSI. Concrete C30/37 (37 N/mm² cube strength) = 5,366 PSI.

The Inch: Exactly 25.4 mm

The international inch was defined as exactly 25.4 mm in 1959. This exact relationship simplifies inch-to-metric conversion. Common fractions: ½ in = 12.7mm; ¼ in = 6.35mm; ⅛ in = 3.175mm. Standard rebar cover spacers in the UK are sold in mm increments (20mm, 25mm, 30mm, 40mm, 50mm) — easily converted to approximate inch values for US reference documents.

U-value and R-value are Reciprocals

The thermal transmittance U-value (W/m²K) and the thermal resistance R-value (m²K/W) are reciprocals: R = 1/U and U = 1/R. Lower U-value = better insulation. Higher R-value = better insulation. UK Building Regulations specify limits in U-values (e.g. wall ≤ 0.18 W/m²K). US insulation products are often rated in R-values — important to convert when using US product data in UK designs.

Frequently Asked Questions – Construction Unit Conversion UK 2026

What is the difference between MPa and N/mm²?

There is no difference — 1 MPa = 1 N/mm² exactly. The megapascal (MPa) and the newton per square millimetre (N/mm²) are numerically identical units of stress and pressure. The Pascal is defined as 1 N/m², so 1 MPa = 10⁶ N/m². Since 1 m² = 10⁶ mm², 1 MPa = 10⁶ N/m² = 1 N/mm². In UK Eurocode structural design, N/mm² is the preferred unit for material strengths (concrete fck, steel fy, timber strength values). MPa is used more often in concrete technology, geotechnical, and international contexts. Both are correct and both appear in UK engineering documentation — understanding they are identical eliminates a very common source of confusion.

How do I convert kN/m² to MPa?

To convert kN/m² to MPa, divide by 1,000. This is because: 1 kN/m² = 1 kPa = 0.001 MPa. Conversely, 1 MPa = 1,000 kN/m² = 1,000 kPa. This conversion is used constantly in structural engineering — for example, converting the soil bearing capacity from kN/m² (as reported in a ground investigation) to N/mm² (for checking against foundation contact pressure in N/mm²). A bearing capacity of 150 kN/m² = 0.15 N/mm² = 0.15 MPa.

How do I convert kN to tonnes?

To convert kN to tonnes-force: divide by 9.807 (since 1 tonne-force = 9.807 kN). To convert tonnes-force to kN: multiply by 9.807. In practice, many UK engineers approximate 10 kN ≈ 1 tonne-force (1.98% error), which is acceptable for quick checks but not for final calculations. A column reaction of 500 kN is approximately 51 tonnes-force (500 / 9.807 = 51.0 tf). Note the distinction between tonne (mass) and tonne-force (force): a mass of 1 tonne exerts a force of 9.807 kN under standard gravity.

How many mm in an inch, and how many mm in a foot?

Exactly 25.4 mm in 1 inch and exactly 304.8 mm in 1 foot (= 12 × 25.4). These are exact definitions established by international agreement in 1959. Useful practical values: 1 foot = 304.8mm ≈ 305mm; 1 inch = 25.4mm; 6 inches = 152.4mm; 4 inches = 101.6mm (approximately the face dimension of a UK standard brick plus mortar). In the UK, all structural drawings use mm for dimensions — feet and inches appear only in historical drawings, client briefs referencing American standards, or descriptions of US-imported products.

How do I convert PSI to MPa?

To convert PSI (pounds per square inch) to MPa: divide by 145.038. To convert MPa to PSI: multiply by 145.038. So: 1 PSI = 0.006895 MPa; 1 MPa = 145.038 PSI. Common values: concrete C30/37 (cube strength 37 N/mm²) = 37 × 145.038 = 5,366 PSI; steel S275 yield (fy = 275 N/mm²) = 275 × 145.038 = 39,885 PSI ≈ 40 ksi; tyre pressure 32 PSI = 0.221 MPa = 221 kPa. PSI is not used in UK Eurocode-based structural design but is encountered in US references, hydraulic system specifications, and some material datasheets.

What is the difference between kN/m, kN/m², and kN/m³?

These three units represent different physical quantities used extensively in structural and civil engineering. kN/m is a line load or distributed force per unit length — used for beam self-weight, wall loads on beams, and uniformly distributed loads (UDL) on linear elements (e.g. 15 kN/m on a floor beam). kN/m² is a pressure or area load — used for imposed floor loads, wind pressures, soil pressures, and bearing pressures on foundations (e.g. 1.5 kN/m² domestic floor live load). kN/m³ is a unit weight or force density — used for material self-weights (e.g. concrete 25 kN/m³, steel 78.5 kN/m³, water 9.81 kN/m³). Confusing these three is a common error — always check units carefully in structural calculations.

How do I convert a bending moment from kN·m to N·mm?

To convert kN·m to N·mm: multiply by 10⁶ (one million). This is because 1 kN = 1,000 N and 1 m = 1,000 mm, so 1 kN·m = 1,000 N × 1,000 mm = 1,000,000 N·mm = 10⁶ N·mm. This conversion is needed when checking beam bending capacity using elastic section modulus (Zx in cm³, which must be converted to mm³ = cm³ × 1,000) against the design moment in N·mm. For example: M = 50 kN·m = 50 × 10⁶ N·mm; Zx = 231 cm³ = 231,000 mm³; moment capacity = fy × Zx = 275 × 231,000 = 63,525,000 N·mm = 63.5 kN·m.

How do I convert a roof pitch in degrees to a percentage or 1-in-N ratio?

To convert degrees to percentage gradient: % = tan(degrees) × 100. To convert to 1-in-N ratio: N = 1/tan(degrees). Examples: 30° roof pitch = tan(30°) × 100 = 57.7% gradient = 1 in 1.73. 15° (minimum for concrete tiles) = tan(15°) × 100 = 26.8% = 1 in 3.73. 45° = tan(45°) × 100 = 100% = 1 in 1. In UK roofing, pitch is commonly expressed in degrees (BS 5534); drainage gradients in civil engineering are expressed as a percentage or 1-in-N ratio. The slope / angle converter above does all these conversions automatically.

What is the difference between U-value and R-value?

The U-value (thermal transmittance) measures how quickly heat passes through a building element — lower U-value means better insulation. Units: W/m²K. Used in UK Building Regulations Part L and EC Eurocodes. The R-value (thermal resistance) is the reciprocal of U-value: R = 1/U. Higher R-value means better insulation. Units: m²K/W. R-values are used in North America and appear on many insulation product specifications. To convert: if a product has R-value 4.3 m²K/W, its U-value = 1/4.3 = 0.23 W/m²K. Individual layer R-values (R = thickness/λ) add together to give the total wall R-value, from which the U-value is calculated as U = 1/R_total.